CVE-2026-12617
Analyse NVD en cours
The issue is unexpected program termination based on ordering and/or specific content in responses to queries for CNAME or DNAME, and A records. Specifically, if a client queries for a DNAME and A record below the DNAME to the resolver, and the authoritative server responds positively to the A query but delays the DNAME response and later responds negatively, `named` may quit unexpectedly. Or, if a client queries for a CNAME and A record for the same name to the resolver, and the authoritative server responds positively to the A query but delays the CNAME response and later responds with a self-referential CNAME, the same failure may occur. This issue affects BIND 9 versions 9.18.0 through 9.18.50, 9.20.0 through 9.20.24, 9.18.11-S1 through 9.18.50-S1, and 9.20.9-S1 through 9.20.24-S1.
Ce que ça veut dire
- Exposition
- Exploitable à distance depuis le réseau, sans authentification et sans action de la victime.
- Impact
- Un attaquant peut mettre le service hors ligne.
- Probabilité
- Le score EPSS reste bas : rien n’annonce une exploitation imminente, ce qui ne dispense pas de corriger.
À faireÀ intégrer au prochain cycle de correctifs. Commencer par les instances exposées à Internet.
Lecture automatique du vecteur CVSS, du type de faiblesse (CWE) et du score EPSS. La description technique ci-dessus reste celle publiée par le NIST, en anglais.