FR
live
High CVSS 8.8

CVE-2026-11826

OpenPLC_v3 contains a heap-based buffer overflow in the getData() function in webserver/core/modbus_master.cpp. getData() reads characters between two delimiters into a caller-supplied buffer with no size parameter and no bounds check. In parseConfig() the function is invoked with the 100-byte heap-allocated MB_device.dev_name field. An authenticated attacker with access to the OpenPLC web interface can send a crafted HTTP POST to the /modbus endpoint with an oversized device_name value; the value is persisted to mbconfig.cfg and parsed on load, overflowing dev_name and overwriting adjacent struct fields (protocol at offset 108, dev_address at offset 109, ip_port at offset 210). A 200-byte payload writes 100 bytes past the allocation. The result is heap corruption leading to runtime crash and denial of service of the PLC process control loop, with attacker-controlled overwrite of adjacent configuration fields. The upstream repository was archived on 2026-04-04 and no fix is expected; the vendor has confirmed the issue does not affect OpenPLC Runtime v4.

What this means

Exposure
Exploitable remotely over the network, with an ordinary user account and with no action from the victim.
Impact
An attacker can read sensitive data, modify or destroy data and take the service offline.
Weakness
A heap overflow corrupts allocator structures and can lead to code execution.
Likelihood
Its EPSS score stays low: nothing points to imminent exploitation, which is no reason to leave it unpatched.

What to doFold into the next patch cycle.

Read automatically from the CVSS vector, the weakness type (CWE) and the EPSS score. The technical description above remains the one published by NIST.

Published
18 July 2026
CVSS
8.8 (v3.1) CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS
0.42% probability of exploitation within 30 days · above 35% of all CVEs
Weakness
CWE-122
Sources
nvd
References

Type at least two characters.

navigate open esc dismiss